Technical Resources
Firestop Reference Library
Manufacturer system selectors, industry standards, and code references used by Horizon Firestop crews and project engineers. All links open the source document or tool directly.
System Selector Tools
Interactive tools from leading firestop manufacturers to identify listed assemblies for your specific penetration conditions.
3M Fire Barrier System Selector
Search 3M's full library of UL-listed firestop systems by substrate, penetrant type, annular space, and F/T rating. Generates submittal-ready system documentation.
Hilti Firestop System Selector
Hilti's online selector for CP and CFS series firestop products. Filter by construction type, penetrant, and required fire rating to find the correct listed assembly.
STI Firestop System Selector
Specified Technologies Inc. online system selector for SpecSeal and EZ Path products. Search UL-listed assemblies by wall or floor type, penetrant, and annular space to generate submittal documentation.
ASTM Standards
American Society for Testing and Materials test methods that govern firestop system performance evaluation and listing.
ASTM E814 — Fire Tests of Through-Penetration Fire Stops
Standard test method for evaluating the fire resistance of through-penetration firestop systems. Establishes F-Rating and T-Rating criteria used in UL listings.
ASTM E1966 — Fire-Resistive Joint Systems
Test method for fire-resistive joint systems including head-of-wall, floor-to-floor, and construction joints. Basis for UL 2079 listed assemblies.
ASTM E2307 — Perimeter Fire Containment Systems
Standard test method for determining fire resistance of perimeter fire barrier systems using the intermediate-scale, multi-story test apparatus.
UL Standards & Listings
Underwriters Laboratories standards and the online directory of UL-listed firestop assemblies referenced on submittals and inspection reports.
UL 1479 — Through-Penetration Firestop Systems
UL's standard for through-penetration firestop systems. All UL-listed through-penetration assemblies (WL, WJ, FL, FJ, CAJ series) are tested under this standard.
UL 2079 — Fire-Resistive Joint Systems
UL's standard for fire-resistive joint systems including head-of-wall and construction joints. Listed assemblies carry HW, WW, and FF designations.
UL Product iQ — Firestop Assembly Directory
Search the complete UL database of listed firestop assemblies. Look up any system number from a submittal or inspection report to verify current listing status.
NFPA Codes & Standards
National Fire Protection Association codes that mandate firestop installation requirements in commercial and healthcare construction.
NFPA 101 — Life Safety Code
The primary life safety code adopted by most jurisdictions and required for healthcare occupancies under Joint Commission standards. Section 8.3 governs fire barriers and through-penetration protection.
NFPA 5000 — Building Construction and Safety Code
NFPA's comprehensive building code covering fire-resistive construction, compartmentalization, and through-penetration firestop requirements for new construction.
NFPA 285 — Exterior Wall Assemblies
Standard fire test method for evaluation of fire propagation characteristics of exterior non-load-bearing wall assemblies. Relevant for perimeter firestop at curtain wall and window wall systems.
CSI MasterFormat Codes
Construction Specifications Institute division codes covering the scopes Horizon Firestop self-performs. Use these codes when writing specifications, submittals, or RFIs.
Division 07 — Firestopping & Joints
Division 09 — Coatings & Fireproofing
Division 22 — Plumbing Insulation
Division 23 — HVAC Insulation
Division 27 — DAS & Communications
Need Help Selecting a System?
Our team can help identify the right listed assembly for your project conditions. Send us your plans or penetration details and we'll get back to you quickly.